Data Center Duct Bank Spacers

Custom HDPE conduit arrays for data center primary service, MV/HV feeders, generator ties, fiber and communications, and mixed-size banks. CNC-cut in Greenville, SC and shipped to the jobsite.

Request a Quote

Banks we cut for data centers

Primary service

Entrance and primary duct banks that bring utility or campus power into the building.

MV/HV feeders

Medium- and high-voltage feeder banks with the conduit sizes on your one-line and duct section.

Generator ties

Generator and standby ties, including boards that mix large power conduits with smaller control conduits.

Fiber and communications

Fiber, communications, and other low-voltage conduits in their own bank or sharing a sheet with power.

Mixed-size banks

One sheet can carry more than one conduit size. Columns and rows follow the duct section, not a catalog grid.

Power and fiber spacing

When power feeders and fiber share a bank, call out the center-to-center spacing the engineer wants between power and communications conduits. We cut that spacing into the sheet. We do not assign an EMI clearance for you.

Hyperscale and AI campuses

Hyperscale and AI campus sites often put primary service, feeder banks, and generator ties on the same civil package, with long runs and repeating spacer intervals. We cut the boards from those drawings in Greenville, SC.

Multi-row bank schematic

Schematic placeholder — not a photograph of a finished bank or of another manufacturer’s product.

  • Top row: larger power conduits
  • Middle rows: additional power or mixed sizes
  • Lower row: fiber and communications, spaced from the power rows on the drawing
  • One CNC-cut HDPE sheet holds that grid
  • The next sheet repeats about every 4–7 ft along the duct bank

Related pages

Questions

Which data center banks can you space?

Primary service, MV/HV feeders, generator ties, fiber and communications, and mixed-size banks. Send the conduit schedule and we will cut the hole array to that drawing.

Can one board hold power and fiber?

Yes, when the drawing calls for a mixed bank. Tell us the center-to-center spacing between power and communications conduits. We cut that spacing; we do not assign an EMI clearance for you.

Ready to quote a data center duct bank?

Send the conduit schedule for primary service, feeders, generator ties, or a mixed power and fiber bank. We CNC-route the HDPE sheet in Greenville, SC.